CoreGrid Engineering

Engineering service

Power System & Protection Studies

Network and system studies that support substation, renewable, pooling, storage and HVDC design: load flow, short-circuit, insulation coordination, harmonics, transients, protection coordination, reactive power and grid interconnection. Each is offered on a stated basis.

Studies and their basis

“Prepared” means we carry out the study. “Prepared or reviewed” means either, depending on the contract. Where specialist or OEM input is needed, the proposal says so. Anything not listed here is confirmed at enquiry before it is offered.

StudyQuestion it answersTypical inputsBasis
Load Flow / Power Flow StudyDo voltages, loading and reactive flows meet requirements in the operating cases?Network model, operating cases, generation and load dataPrepared or reviewed, by scope
Short-Circuit / Fault Level StudyWhat fault currents must equipment withstand and protection detect?Grid data, network impedancesPrepared or reviewed, by scope
Insulation Coordination StudyAre arrester ratings and equipment withstand levels coordinated?System voltages, arrester and equipment dataPrepared or reviewed, by scope
Harmonic Analysis / Harmonic Load Flow StudyAre distortion limits met, and is a filter needed?Emission data, network impedance, limitsBy scope, with specialist input where needed
VFTO Study for GISWhat very fast transient overvoltages can switching create in GIS? Different from a lightning study.GIS layout and supplier data, switching casesWhere appropriate, and only when models and specialist input are available; confirmed at enquiry
Switching Transient / Transient Overvoltage StudyWhat overvoltages do switching operations cause, and are the margins adequate?Detailed network and equipment models, switching casesWhere required, as applicable to the contracted scope
Protection Coordination / Selectivity StudyDo protection devices discriminate correctly for faults and overloads?Network model, relay and CT dataPrepared or reviewed, by scope. Relay setting sheets follow from it
Reactive Power Compensation / Voltage Regulation StudyHow much compensation keeps voltage and power factor in range?Network model, capability curves, grid-code limitsWhen applicable, by scope
Grid Interconnection / Grid Connectivity StudyCan a renewable plant, pooling substation or BESS connect at the chosen point and voltage?Plant and grid data, connection approval, grid-code requirementsRenewable, pooling and BESS, as contracted

Kept separate on purpose

Design calculations and line calculations are not network studies.

Electrical design calculations

Earthing grid design, DSLP, busbar sizing, sag–tension and short-circuit force, battery, cable and illumination calculations, and relay setting calculations are design calculations, not network studies.

Electrical design calculations

Transmission line sag–tension

Conductor sag–tension and stringing charts for overhead lines are line calculations and are kept on the transmission page.

Sag–tension and stringing charts

Relay setting sheets

Setting sheets are the deliverable that follows from a protection coordination study. They are listed with the design calculations, so they are not counted as a second network study.

Studies in the deliverables library

How a study is carried out

Data

System and equipment data are collected from the client and suppliers, with gaps listed and assumptions agreed.

Model and cases

The model and the study cases are set out before results are produced, so the client can confirm the scenarios.

Results

Results are compared with the project’s acceptance limits, and any non-compliance is stated plainly.

Design decisions

Recommendations go back into the design: equipment ratings, filters, protection settings inputs or layout.

Software and what it is used for

SoftwareTypical use
SES‑CDEGSEarthing and grounding analysis: GPR, step and touch potentials (specialist earth-system analysis)
ETAPLoad flow, short-circuit and protection coordination studies, using the modules available for the contract
PSCAD/EMTDCElectromagnetic transient studies (for example switching or GIS VFTO), only where models and specialist input are available
PLS-CADDOverhead line profiling, tower spotting, sag–tension and stringing charts (not substation busbar SCF)
STAAD.ProStructural analysis and design
DIALux evoIndoor and outdoor illumination calculation and layout
AutoCADElectrical and civil drawings

These programs are named in the company profile as working tools. Their availability and the modules used on a given contract, the model data and any specialist input are confirmed at enquiry; the client’s specification decides when a particular program or version is required.

Product names belong to their owners. Listing them describes working tools; it is not an endorsement or a partnership.

Share your SLD, technical specification or MDL for an engineering proposal

Send us the tender extract, single-line diagram, master deliverable list or the specific calculation you need. We will confirm scope, inputs and a realistic submission sequence before any work starts.